VIN Technologies › Labs › Basic Electrical Lab
AC power and power factor
Basic Electrical Lab · free online experiment, runs in your browser with no install or sign-up.
Open this experiment in the circuit simulator
Objective
Measure the RMS voltage and current, real power and power factor of an R–L load on 50 Hz mains-style supply.
Procedure
- Run and compare the voltage and current waveforms: the current lags.
- Change L to 0: the power factor becomes 1.
Theory
|Z| = √(R² + (ωL)²) = 137.4 Ω, I_rms = V_rms/|Z| = 51.5 mA, P = I²R, PF = cos φ = R/|Z| = 0.728 (lagging).
Questions to answer
- Why do utilities charge for reactive power?
Components used
Function generator (sine), Inductor 100uH, Oscilloscope (2-channel), Resistor 220 ohm 1/4W
About the model
Ideal wires; component models as listed in the catalogue (no parasitics, no temperature drift). Built without a breadboard so the schematic stays readable.
Open this experiment in the circuit simulator